The Perfect Test & Measurement Partner

Anritsu - Vector Network Analyzers (VectorStar™)

MS464xB

Broadest Frequency Span from A Single Coaxial Test Port Covering 70 kHz to 70 GHz

The VectorStar™ family is Anritsu's Premium VNA line, providing the highest overall performance on a modern platform. The MS4640B VectorStar™ VNA offers the broadest coverage in a single instrument, 70 kHz to 70 GHz. The additional two decades at the low end are even more impressive than the guaranteed 70 GHz coverage on the high end.


Highest Performance Pulse Measurements with PulseView™

PulseView™, when combined with the innovative IF digitizing option, offers industry-leading 2.5 ns pulse resolution and 100 dB dynamic range with no compromises or trade-offs due to varying duty cycles. PulseView™ provides real time display of pulse measurements while dynamically modifying pulse parameters for immediate design validation.


4-port Single-ended or Balanced Measurements using DifferentialView™ Analysis

DifferentialView™, when combined with the dual internal source option, offers real time display analysis of differential devices, drivers, and components while actively modifying phase and magnitude relationships of the internal dual sources.


Broadband Noise Figure Measurements from 70 kHz to 125 GHz

The noise figure option is based on a cold source technique for improved noise figure measurement accuracy. VectorStar™ is the only VNA platform capable of measuring noise figure from 70 kHz to 125 GHz and available with an optimized noise receiver for measurements from 30 GHz to 125 GHz.


Upgrade the VectorStar™ MS464xB VNAs to the Broadband Performance of ME7838A

Upgrade paths available to expand VectorStar™ MS464xB VNAs to the broadband performance of ME7838A.


Download MS4640B Quick Factsheet for more features


Basic Performance

Parameters / Characteristics Specifications
Frequency Range 10 MHz to 20 GHz (MS4642B)
10 MHz to 40 GHz(MS4644B)
10 MHz to 50 GHz (MS4645B)
10 MHz to 70 GHz (MS4647B)
Resolution 1 Hz
Output Level Setting Range MS4642B, 20 GHz model, standard no-options
  -25 to +10 dBm (70 kHz < f ≤ 10 MHz)
  -25 to +12 dBm (10 MHz < f ≤ 2.5 GHz)
  -20 to +13 dBm (2.5 GHz < f ≤ 20 GHz)
MS4644B, 40 GHz model, standard option
  -25 to +10 dBm (70 kHz < f ≤ 10 MHz)
  -25 to +12 dBm (10 MHz < f ≤ 2.5 GHz)
  -20 to +9 dBm (2.5 GHz < f ≤ 20 GHz)
  -25 to +9 dBm (20 GHz < f ≤ 40 GHz)
MS4645B and MS4647B, 50 & 70 GHz model, standard no-options
  -25 to +10 dBm (70 kHz < f ≤ 10 MHz)
  -25 to +12 dBm (10 MHz < f ≤ 2.5 GHz)
  -20 to +6 dBm (2.5 GHz < f ≤ 5 GHz)
  -20 to +5 dBm (5 GHz < f ≤ 20 GHz)
  -25 to +6 dBm (20 GHz < f ≤ 38 GHz)
  -25 to +5 dBm (38 GHz < f ≤ 50 GHz)
  -25 to 0 dBm (50 GHz < f ≤ 65 GHz)
  -25 to -2 dBm (65 GHz < f ≤ 67 GHz)
  -25 to -3 dBm (67 GHz < f ≤ 70 GHz)
Accuracy Measured at default power level
±1.5 dB (70 kHz < f < 10 MHz)
±1.5 dB (10 MHz ≤ f ≤ 40 GHz)
±3.0 dB (40 GHz ≤ f ≤ 67 GHz)
±4.0 dB (67 GHz ≤ f ≤ 70 GHz)
Linearity Measured between default and 5 dB below default port power
±1.5 dB (70 kHz < f < 10 MHz)
±1.0 dB (10 MHz ≤ f ≤ 40 GHz)
±1.0 dB (40 GHz ≤ f ≤ 67 GHz)
±2.0 dB (67 GHz ≤ f ≤ 70 GHz)
Resolution 0.01 dB
Signal Purity Spurious / Harmonics < -20 dBc
Spurious / Non-harmonics Measured at default power, &ge 1 kHz offset
< -20 dBc (70 kHz ≤ f ≤ 10 MHz)
< -30 dBc (10 MHz ≤ f ≤ 70 GHz)
SSB Phase Noise CW, 10 kHz offset
< -78 dBc/Hz (70 kHz < f ≤ 10 MHz)
< -84 dBc/Hz (10 MHz < f ≤ 5 GHz)
< -78 dBc/Hz (5 GHz < f ≤ 10 GHz)
< -72 dBc/Hz (10 GHz < f ≤ 20 GHz)
< -66 dBc/Hz (20 GHz < f ≤ 40 GHz)
< -61 dBc/Hz (40 GHz < f ≤ 70 GHz)
Download MS464xB Brochures for complete specifications




Options Descriptions / Documentations
Basic Hardware MS4642B VNA, 10 MHz to 20 GHz, 2-port, K(male)
MS4644B VNA, 10 MHz to 40 GHz, 2-port, K(male)
MS4645B VNA, 10 MHz to 50 GHz, 2-port, V(male)
MS4647B VNA, 10 MHz to 70 GHz, 2-port, V(male)
Optional Option 002 Time Domain with advanced capabilities
Option 007 Receiver Offset with Multiple Source Control for frequency-translated measurements
Option 031 Second Source
Option 035 IF Digitizer
Option 041 Noise Figure
Option 042 PulseView™
Option 043 DifferentialView™
Option 05x Direct Access Loops for total measurement flexibility
Option 06x Active Measurement Suites with 2 or 4 attenuators
Option 070 70 kHz Low-end Frequency Extension for an unprecedented frequency coverage
Option 08x Broadband / Milllimeter Wave Interface
MN469xB 4-port Test Sets, K and V for 70 kHz to 70 GHz multi-port solutions
Warranty Service Standard3 Years Warranty Service



Loading... in progress



Loading... in progress


Note: All trademarks that appear on this website are the property of their respective owners.


ME7838A

The VectorStar™ Broadband ME7838A system begins a new era in broadband characterization offering many advances in broadband performance including:

  • Industry-best broadband frequency coverage - starts at 70 kHz instead of 10 MHz and operational from 40 kHz to 125 GHz
  • Industry-best dynamic range: 108 dB vs 83 dB at 65 GHz and 107 dB vs 87 dB at 110 GHz
  • Industry-best measurement speed: 55 ms vs 500 ms for 201 pts
  • Industry-best calibration and measurement stability: 0.1 dB vs 0.6 dB over 24 hrs
  • Compact, lightweight mm-wave modules for easy, precise, and economical positioning on the wafer probe station - 0.6 vs 7.6 lb and 1/50 the volume

2 and 4 Port VectorStar™ ME7838A Operating with External mm-wave Modules

The VectorStar™ ME7838A mm-wave system combines the MS4640B series VNA and 3739B test set to control 2 external mm-wave modules for measurement frequencies from 110 GHz to 750 GHz and higher in waveguide bands. The 3739B test set routes the internal RF and LO signals from VectorStar™ thus eliminating the need for external sources. If 4 ports are required, a SM6586 test set and the MN4697B 4 port test set with 2 additional modules can be attached. OML or VDI modules may be used.


First mm-wave System with Real-time Electronic Power Leveling

The real-time power leveling in this VNA system, has best-in-class stability with the widest power level control advantage. The mm-wave system detects IF and RF power and provides correction to the mm-wave power in real time and without the need for software correction feedback. Thus eliminates power correction time lag found on alternative systems using software correction feedback method.


Accurate, Stable Power Control with Widest Power Sweep for Safe, Accurate Gain Compression Measurements

The real-time power leveling method delivers stable mm-wave power even at low levels and reduces the risk of overdriving power-sensitive mm-wave devices - inherent in other systems. Thus, power sweep is available in an industry-leading range of up to 55 dB and without the need for mechanical attenuators in the mm-wave module.


On Wafer Measurments Made Easy

wafer_probe.jpg

For on-wafer measurements, VectorStar offers the smallest, lightest and easiest to position frequency extension modules which connect directly to wafer probes. Bulky, difficult-to-mount frequency extension modules are a thing of the past, even when working with 4-port measurements.







Download ME7838A Quick Factsheet for more features


Basic Performance

Parameters / Characteristics Specifications
Frequency Range 70 kHz to 110 GHz (operational 40kHz to 125 GHz)
Resolution 1 Hz
Output Level Setting Range -25 to +10 dBm (70 kHz < f ≤ 2.5 GHz)
-25 to 0 dBm (2.5 GHz < f ≤ 24 GHz)
-30 to -4 dBm (24 GHz < f ≤ 54 GHz)
-55 to -4 dBm (54 GHz < f ≤ 60 GHz)
-55 to +1 dBm (60 GHz < f ≤ 67 GHz)
-55 to -2 dBm (67 GHz < f ≤ 80 GHz)
-55 to -6 dBm (80 GHz < f ≤ 85 GHz)
-55 to -4 dBm (85 GHz < f ≤ 90 GHz)
-55 to -2 dBm (90 GHz < f ≤ 95 GHz)
-55 to 0 dBm (95 GHz < f ≤ 105 GHz)
-50 to -3 dBm (105 GHz < f ≤ 110 GHz)
Accuracy Measured at default power level
±1.5 dB (70 kHz < f < 10 MHz)
±1.0 dB (10 MHz ≤ f ≤ 24 GHz)
±1.5 dB (24 GHz ≤ f ≤ 54 GHz)
±2.0 dB (54 GHz ≤ f ≤ 95 GHz)
±3.0 dB (95 GHz ≤ f ≤ 110 GHz)
Linearity Measured at default power level
±1.5 dB (70 kHz < f < 10 MHz)
±1.0 dB (10 MHz ≤ f ≤ 54 GHz)
±1.5 dB (54 GHz ≤ f ≤ 95 GHz)
±2.0 dB (95 GHz ≤ f ≤ 110 GHz)
Resolution 0.01 dB
Download MS464xB Brochures for complete specifications




Options Descriptions / Documentations
Basic Hardware ME7838A MS4647A VectorStar™ VNA, 70 kHz to 70 GHz
3739B Broadband Test Set and interface cables
3743A Millimeter-Wave Modules, 2 each
Optional Option 002 Time Domain with advanced capabilities
Option 007 Receiver Offset with Multiple Source Control for frequency-translated measurements
Option 041 Noise Figure
Option 05x Direct Access Loops for total measurement flexibility
Option 06x Active Measurement Suites with 2 or 4 attenuators
Option 070 70 kHz Low-end Frequency Extension for an unprecedented frequency coverage
Option 08x Broadband / Milllimeter Wave Interface
Bias Tees SC8215 Bias Tee providing DC bias from 70 kHz to 110 GHz
SC7287 Bias Tee providing DC bias from 100 MHz to 110 GHz
Warranty Service Standard1 Year Warranty Service



Loading... in progress



Loading... in progress


Note: All trademarks that appear on this website are the property of their respective owners.


Need more information?

Chat with our Technical Support now !
or
Contact us by filling up our online form or email us directly at info@elecsoftsolution.com.