The Chroma 13100 Electrolytic Capacitor ORDERING INFORMATION Analyzer is a general measurement instrument designed for analyzing the features of electrolytic capacitor s. It has multiple functions that can be programmed based on the capacitor features by altering the settings to test metal oxidization thin-film withstand voltage, capacitor leakage current, capacitance, dissipation factor, impedance and equivalent serial resistance, etc.
Used with the special designed sequential switch test box A131001, it can complete the test for multiple capacitors or aluminum foil rapidly, accurately and simultaneously in a short time without changing any test wire.
The report printing function is capable of printing the test results correctly and completely; and the built-in data calculation function can compute the test data of the product instantly for CPK analysis. To avoid the inefficient calculation process done manually, a test software application is also available for you to create a quality report easily. It meets the EIAJ RC-2364A regulations for electrolytic capacitor test and is a test instrument of choice.
Chroma A131001 is a sequential switch test box of ten channels specially designed for Chroma 13100. Each test socket on the test box is implemented with Kelvin measurement, which is suitable for the precise measurement requirement for low impedance and low leakage current. With the SCAN function in 13100 it is able to control the C, D, Q, Z, ESR and LC tests for electrolytic capacitor to be done consecutively without switching the capacitor manually. This increases the test efficiency significantly as it costs only 1/10 of the original test time.
Parameters / Characteristics | Specifications | ||
---|---|---|---|
11300 | |||
Test Parameters | Z/C/D/Q/ESR | ||
Test Frequencies | Available 7 test frequencies from 100~100kHz for selection | ||
Basic Measurement Accuracy | 0.1% | ||
Display | 320 x 240 dot-matrix LCD display |
Checking with Chroma...
Model Number | Basic Measurement Accuracy | Test Parameters |
---|---|---|
13100 Electrolytic Capacitor Aalyzer | 0.1% | Z/C/D/Q/ESR |
11200 Capacitor Leakage Current / IR Meter | 0.3% | LC, IR |
11800/11801/11810 Ripple Current Tester | 0.3% |
Note: All trademarks that appear on this website are the property of their respective owners.
The 11200 Capacitor Leakage Current / IR Meter is Chroma's newest digital leakage cur rent meter. I t provides DC 1~650V, 0 . 5~5 0 0mA ( 1 5 0mA f o r V>1 0 0V) o r DC1~800V, 0.5~500mA (50mA for V>100V) DC power source wi th vol tage meter and nano-ampere meter. Mainly used for electrolytic capacitor leakage current testing, and aluminum-foil withstand voltage testing (EIAJ RC-2364A). And also can be used for active voltage checking or leakage current testing of absorber, zener diode, neon lamp, etc. Standard RS-232 interface, optional GPIB & Handler interface, high speed and stable measurement capabilities enable the Chroma 11200 can be used for both component evaluat ion on the product ion l ine and fundamental leakage current or IR testing for bench-top applications.
Parameters / Characteristics | Specifications | ||||
---|---|---|---|---|---|
11200 (650V) | 11200 (800V) | ||||
Main Function | Capacitor Leakage Current / IR Meter | ||||
Test Parameter | LC, IR | ||||
Test Signal | Voltage | 1.0 V~100 V, step 0.1 V; 101V~650 V,step 1V; ±( 0.5% + 0.2V) |
1.0 V~100 V, step 0.1 V; 101V~800 V,step 1V; ±( 0.5% + 0.2V) |
||
Charge Current Limit | V ≤ 100V: 0.5mA~500mA, 50W max. V > 100V: 0.5mA~150mA, 97.5W max. step 0.5mA; ±( 3% + 0.05mA) |
V ≤ 100V: 0.5mA~500mA, 50W max. V > 100V: 0.5mA~50mA, 40W max. step 0.5mA; ±( 3% + 0.05mA) |
|||
Measurement Display Range | LC : 0.001µA~20.00mA | ||||
Basic Measurement Accuracy | LC Reading : ±(0.3% + 0.005µA) | ||||
Measurement speed (Ext. Trigger, Hold Range, Line Frequency 60Hz) | Fast | 77 ms | |||
Medium | 143 ms | ||||
Slow | 420 ms | ||||
Function | Correction | Null zeroing | |||
Test Voltage Monitor | Vm: 0.0 V~660.0V; ±(0.2% of reading + 0.1V) | Vm: 0.0 V~900.0V; ±(0.2% of reading + 0.1V) | |||
Charge Timer | 0~999 sec. | ||||
Dwell Timer | 0.2~999 sec. | ||||
Foil WV Tester | Test Parameter | handler (50pin), GPIB, RS-232 | |||
Test Signals | Voltage Limit | Tr (Rise Time), Vt (Foil Withstand Voltage) | |||
Constant Charge Current | 650 V typical | 800 V typical | |||
Test Display Range | Tr (Rise Time) | 0.05~600.0 sec. | |||
Charge Voltage | 0.1V~660.0V | 0.1V~900.0V | |||
Test Time | 30~600 sec | ||||
Interface | RS-232(Standard), Handler, GPIB (Optional) | ||||
Display | 240 x 64 dot-matrix LCD display | ||||
Trigger | Internal, External, Manual, BUS |
Checking with Chroma...
Model Number | Basic Measurement Accuracy | Test Parameters |
---|---|---|
13100 Electrolytic Capacitor Aalyzer | 0.1% | Z/C/D/Q/ESR |
11200 Capacitor Leakage Current / IR Meter | 0.3% | LC, IR |
11800/11801/11810 Ripple Current Tester | 0.3% |
Note: All trademarks that appear on this website are the property of their respective owners.
The Chroma 11800/11801/11810 Ripple Current Tester is a precision tester designed for electrolytic capacitors load life testing. It provides constant ripple current output and constant peak voltage (Vpeak = Vdc + Vac_peak) output digital control function. Let load life testing for electrolytic capacitors becomes easier and more reliable. And, the Chroma 11800/11801/11810 use excellent output amplifier design technology to reduce power consumption and internal temperature rising. For long time testing requirement, it can reduce electricity cost and perform high stability. The Chroma 11800/11801/11810 is a just right test solution for electrolytic capacitors quality evaluation.
Parameters / Characteristics | Specifications | |||||
---|---|---|---|---|---|---|
11800 | 11801 | 11810 | ||||
Ripple Current Source | Current Output Range | 0.01~30A | 0.01~10A | |||
Frequency | 100Hz/ 120Hz/ 400Hz/ 1kHz ±0.1% | 20kHz ~ 100kHz | 20kHz ~ 1MHz | |||
Accuracy | 0.030A~0.199A | ± (0.5% of reading + 0.1% of range) | ± (3% + 0.005 A) | 0.03 ~ 0.39A, ± (3% + 0.01 A), 0.40 ~ 10.0A, ± (2% + 0.05 A) | ||
0.20A~1.99A | ± (2.5% + 0.05 A) | |||||
2.0A~10A | ± (2% + 0.2 A) | |||||
10.0A~30A | - | |||||
Ripple Voltage Output Range | 90Vrms / 10Arms, 30Vrms / 30Arms | 15Vrms maximum | ||||
DC Bias Voltage Source | Voltage Output Range | DC 0 ~ 500V, ± (0.3% + 0.05V) | ||||
Charge Current | 200mA, 40W Maximum | |||||
Signal Monitor Parameter Accuracy | Irms (Ripple Current) | 0.001A~0.199A | ± (0.5% of reading + 0.1% of range) | ± (2% + 0.005 A) | 0.030A ~ 0.399A: ± (3% +0.01A), 0.400A ~ 10.00A: ± (2% +0.05A) | |
0.20A~1.99A | ± (2% + 0.05 A) | |||||
2.0A~10A | ± (2% + 0.2 A) | |||||
10.0A~30A | - | |||||
Vpeak (Normally, set to capacitor rated voltage) | Vpeak =Vdc + Vac_peak | |||||
Vdc (DC Bias Voltage) | ± (0.3% + 0.05V) | |||||
Vrms (Ripple Voltage) | 0 ~ 1.99V, ± (0.3% of reading + 0.5% of range) 2.00 ~ 19.99V, ± (0.3% of reading + 0.1%of range) 20.00V ~ 200.0V, ± (0.3% of reading + 0.1%of range) |
± (1% + 0.005V) | ± (1% + 0.01V) | |||
Control Function | Timer | 1 min~10000 hour, 30min error per year | ||||
Interface | RS-485 (Standard) | |||||
Display | 320 x 240 dot-matrix LCD display | |||||
Operation | Start, Stop, Continue | |||||
Protection | OCP, OTP, Over Load |
Checking with Chroma...
Model Number | Basic Measurement Accuracy | Test Parameters |
---|---|---|
13100 Electrolytic Capacitor Aalyzer | 0.1% | Z/C/D/Q/ESR |
11200 Capacitor Leakage Current / IR Meter | 0.3% | LC, IR |
11800/11801/11810 Ripple Current Tester | 0.3% |
Note: All trademarks that appear on this website are the property of their respective owners.