The Chroma 11021/11021-L LCR Meter are the most cost-effective digital LCR Meter, provides 100Hz, 120Hz, 1kHz, and 10kHz test frequencies for the 11021 and 1kHz, 10kHz, 40kHz, 50kHz test frequencies for the 11021-L. Standard RS-232 interface, optional GPIB & Handler interface, high speed and stable measurement capabilities enable the Chroma 11021/11021-L can be used for both component evaluation on the production line and fundamental impedance testing for bench-top applications.
The Chroma 11021/11021-L use lower harmonicdistortion phase-detection technology to reduce affection of measurement accuracy caused by hysteresis distortion in magnetic component or high dielectric-coefficient capacitor measurement, which is not provided in general low-end LCR Meters.
The 11021-L is the ideal selection for high frequency coil, core, choke, and etc. passive components incoming/outgoing material quality inspect and automatic production.
Parameters / Characteristics | Specifications | |||
---|---|---|---|---|
11021 | 11021-L | |||
Measurement Parameter | Primary Display | L, C, R, |Z| | ||
Secondary Display | Q, D, ESR, Xs, θ | |||
Test Signal Information | Test Level | 0.25V / 1V , ±(10% + 3 mV) | 50mV/ 1V, ±10%+3mV | |
Test Frequency | 100Hz, 120Hz, 1kHz, 10kHz (9.6kHz) | 1kHz, 10kHz, 40kHz, 50kHz | ||
Frequency Accuracy | ±0.25% | ±0.02% | ||
Output Impedance (Typical) | Varies as range resistors 25, 100, 1k, 10k, 100k | |||
Measurement Display Range | Primary Parameter | L: 0.01µH ~ 9.999kH, C: 0.01pF ~ 99.99mF, R,lZl: 0.1m. ~ 99.99MΩ | ||
Secondary Parameter | Q: 0.1 ~ 9999.9, D: 0.0001 ~ 9999.9, θ: -180.00°~ +180.00° | |||
Basic Accuracy | ±0.1% | ±0.2% | ||
Measurement Time (1kHz) | Fast | Freq = 1k/10kHz : 75ms Freq = 100/120Hz: 85ms |
Freq = 1kHz/10kHz : 75ms Freq = 40kHz : 105ms Freq = 50kHz : 90ms |
|
Medium | 145ms | Freq.=1kHz/10kHz 145ms Freq.=40kHz 185ms Freq.=50kHz 150ms |
||
Slow | 325ms | Freq.=1kHz/10kHz 325ms Freq.=40kHz 415ms Freq.=50kHz 400ms |
||
Trigger | Internal, Manual, External, BUS | |||
Display | L, C, R, |Z|, Q, D, R, θ | 40 x 4 (Character Module) LCD Display | ||
Function | Correction | Open/Short zeroing | ||
Equivalent Circuit Mode | Series, Parallel | |||
Interface & Input/Output | Interface | RS-232 (Standard), Handler & GPIB (Optional) | ||
Output Signal | Bin-sorting & HI/GO/LOW judge | |||
Comparator | Upper/Lower limits in value | |||
Bin Sorting | 8 bin limits in % | |||
Trigger Delay | 0 ~ 9999mS |
Checking with Chroma...
Model Number | Test Frequencies | Basic Accuracy |
---|---|---|
11021 LCR Meter | 100Hz, 120Hz, 1kHz and 10kHz (9.6kHz) (11021) 1kHz, 10kHz, 40kHz, 50kHz (11021-L) |
0.1% (11021), 0.2% (11021-L) |
11022 and 11025 LCR Meters | 0Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, 100kHz | ±0.1% |
11050 HF LCR Meter | 75kHZ~30MHz (11050-30M), 1kHz~10MHz (11050), 60Hz~5MHz (11050-5M) | 0.1% |
11020 Capacitance Meter | 100Hz, 120Hz, 1kHz | 0.1% |
13350 Automatic Transformer Tester | 20Hz~200kHz, ± (0.1% + 0.01Hz), 20Hz~200kHz, ± (0.1% + 0.01Hz), Resolution : 0.001Hz (<1kHz) | ±0.1% |
3250/3252/3302 Transformer Test System | 20Hz~200kHz/1MHz, 0.02% accuracy | 0.1% |
3312 Telecom Transformer Test System | 20Hz~1MHz, 0.02% accuracy | 0.1% |
1320 Bias Current Source | 20Hz~200kHz, 20Hz~1MHz | |
11300 Bias Current Test System | 20Hz to 1MHz | |
A132501 Test Fixture of Auto Transformer Scanning Box Model |
Note: All trademarks that appear on this website are the property of their respective owners.
The Chroma 11022 and 11025 LCR Meters are passive component testers that give you the most cost effective alternative equivalent to other high priced meters. They are designed for the demanding applications of production test, incoming inspection, component design and evaluation. Programmable test signal level settings are from 10mV to 1V in steps of 10mV, and the VM/IM signal level monitor functions allow you to evaluate your devices at the level you specify. Ten test frequencies of 50Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, and 100kHz, can be used to evaluate passive components and transformers/ LF coils.
Other low cost LCR meters on the market have shortcomings when used for low impedance component evaluations, such as the large capacitance of electrolytic capacitors and low inductance of coils. As the 11022/11025 are equipped with high resolution (0.01mΩ) in low impedance, and high accuracy (0.3%) untill 100mΩ range, they can be used to evaluate low impedance components to meet measurement requirements.
The 11025 LCR Meter can also measure DC resistance, turn ratio and mutual inductance of transformers. It is suitable for pulse transformer or LF coil evaluation. Chroma's Transformer Test Fixture used with the 11025, can measure both the primary and the secondary parameters automatically by changing the internal relays in the 11025. With this, there is no need to change the connections required for measuring transformer parameters. With an adjustable internal DC bias current source up to 200mA as a standard function, the 11025 is the right tool for inductance inspection of telecom transformers and small power chokes under DC bias current.
The 11022/11025 LCR Meters provide a powerful combination of features designed to maximize productivity in all testing environments. Measurement speed in the SHORT integration time mode is 15mS(≥100Hz). Handler interface, Pin-out, GPIB Interface, and IEEE 488 commands are compatible with 4263B.
Finally, the 11022/11025 have a built in comparator, 8 bin sorting, trigger delay functions, and handler interface trigger functions, making system integration easy, and improving measurement throughput as well as reliability.
Parameters / Characteristics | Specifications | |||
---|---|---|---|---|
11022 | 11025 | |||
Test Parameter | L,C, R,|Z|, Q, D, ESR, X,θ | L,C, R,|Z|, Q, D, ESR, X,θ DCR4, M, Turns Ratio, L2, DCR2 |
||
Test Signal | Test Frequency | 50Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, 100kHz ; ±0.01% | ||
Test Level | 10 mV~1V , step 10 mV; ±(10% + 3 mV) | |||
Output Impedance | Constant 107X : 25Ω ; Constant 320X : 100Ω ; Constant 106X : 2Ω,for Z≥10Ω, 100mA (1V setting) for reactive load≤10Ω ; Constant 102X : 25Ω, for Z<1Ω, 100Ω for else |
|||
DC Bias Current (Freq. ≥ 1kHz) | - | 50mA max. for Constant 100Ω, 200mA max for Constant 25Ω (AC level ≤ 100mV) |
||
Measurement Display Range | C (Capacitance) | 0.001pF ~ 1.9999F | ||
L, M, L2 (Inductance) | 0.001µH ~ 99.99k | |||
Z (Impedance), ESR | 0.01mΩ ~99.99MΩ | |||
Q (Quality Factor) ; D (Dissipation Factor) | 0.0001 ~ 9999 | |||
θ(Phase Angle) | -180.00° ~ +180.00° | |||
Turns Ratio (Np:Ns) | - | 0.9~999.99 | ||
DCR | - | 0.01mΩ~99.99MΩ | ||
Basic Measurement Accuracy | ±0.1% | |||
Measurement Time (Fast) | 21ms | |||
Interface & I/O | Interface | handler (50pin), GPIB, RS-232 | ||
Output Signal | Bin-sorting & HI/GO/LOW judge | |||
Comparator | Upper/Lower limits in value | |||
Bin Sorting | 8/99 bin limits in %, ABS | |||
Trigger Delay | 0~9999ms | |||
Display | 240 x 64 dot-matrix LCD display | |||
Function | Correction | Open/ Short zeroing, load correction | ||
Averaging | 1~256 programmable | |||
Cable Leng | 0m, 1m, 2m, 4m | |||
Test Sig. Level Monitor | Voltage, Current | |||
Equivalent Circuit mode | Series, Parallel | |||
Memory (Store/ Recall) | 50 instrument setups | |||
Trigger | Internal, Manual, External, BUS |
Checking with Chroma...
Model Number | Test Frequencies | Basic Accuracy |
---|---|---|
11021 LCR Meter | 100Hz, 120Hz, 1kHz and 10kHz (9.6kHz) (11021) 1kHz, 10kHz, 40kHz, 50kHz (11021-L) |
0.1% (11021), 0.2% (11021-L) |
11022 and 11025 LCR Meters | 0Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, 100kHz | ±0.1% |
11050 HF LCR Meter | 75kHZ~30MHz (11050-30M), 1kHz~10MHz (11050), 60Hz~5MHz (11050-5M) | 0.1% |
11020 Capacitance Meter | 100Hz, 120Hz, 1kHz | 0.1% |
13350 Automatic Transformer Tester | 20Hz~200kHz, ± (0.1% + 0.01Hz), 20Hz~200kHz, ± (0.1% + 0.01Hz), Resolution : 0.001Hz (<1kHz) | ±0.1% |
3250/3252/3302 Transformer Test System | 20Hz~200kHz/1MHz, 0.02% accuracy | 0.1% |
3312 Telecom Transformer Test System | 20Hz~1MHz, 0.02% accuracy | 0.1% |
1320 Bias Current Source | 20Hz~200kHz, 20Hz~1MHz | |
11300 Bias Current Test System | 20Hz to 1MHz | |
A132501 Test Fixture of Auto Transformer Scanning Box Model |
Note: All trademarks that appear on this website are the property of their respective owners.
The Chroma 11050 series HF LCR Meter is a precision test instrument designed to accurately measure and evaluate passive components at high speeds. Its measurement capabilities cover the primary and secondary parameters required for testing the inductance, capacitance, resistance, quality factor and loss factor of passive components. The HF LCR Meter has a broad testing frequency range from 75kHz~30MHz/1kHz~10MHz/60Hz~5MHz suitable for analyzing the components' characteristics under different frequencies. Its 0.1% basic measurement accuracy provides stable and highly reliable results. A fast 7ms measurement speed effectively increases productivity when working in an automated environment.
In addition to the excellent measurement features found in other Chroma LCR Meters, the 11050 series includes additional useful functions. It has 3 output impedance modes to satisfy demands of measuring and working with other instruments. The versatile digital display can be configured to best fit the current testing resolution; furthermore, the test signal monitoring function displays the voltage and current that is actually carried to the DUT. The timing settings of trigger delay, measure delay and average number of times allow the measurements to transfer seamlessly to an automated test environment providing accurate results within a limited testing time.
The detached design adopted by the Chroma 11050 series provides several advantages. Since test processing and the display use separate CPUs, the testing speed is increased and shorter test leads are needed when integrated into an automated test environment. Shorter test leads improve the accuracy of high frequency measurements.
Chroma's 11050 series HF LCR Meter has multiple remote interface options. Handler and RS-232C remote interfaces come standard for software or hardware control of test conditions, measurement trigger, judge test results, and collect measured data. The standard USB port saves device settings and controls the output of an external DC bias current source. Optional GPIB and Ethernet remote interfaces are available as well for software control.
Due to the design of modern portable electronic communication devices with thin form factors and low power consumption, required frequency testing of power inductors is increasing. The equivalent series resistance of components has become a critical indicator to identify if it is good or bad. The buffer capacitor plays an important role for overall circuit reliability and must function properly under various voltage transient conditions; the equivalent series resistance must remain at a very low level when operated at high frequencies. The Chroma 11050 series is focused on testing passive components at high frequencies and with enhanced key measurement capabilities during R&D so that it simulates the user's actual application as closely as possible. The increased accuracy of low impedance measurements demonstrates the usefulness of Chroma 11050 series in high frequency testing applications.
The Chroma 11050 series HF LCR Meter was designed with many enhancements and key features to make it the best choice to meet the demands of modern component characterization analysis and high speed testing for automated production line or incoming/outgoing inspection applications.
Parameters / Characteristics | Specifications | ||||
---|---|---|---|---|---|
11050-30M | 11050 | 11050-50M | |||
Test Parameter | L, C, R, Z, Y, Q, D, θ | L, C, R, Z, Y, DCR, Q, D, θ | |||
Test Signal | Test Frequency | 75kHz ~ 30MHz ± (0.1% + 0.01Hz) |
1kHz ~ 10MHz ± (0.1% + 0.01Hz) |
60Hz ~ 5MHz ± (0.1% + 0.01Hz) |
|
Test Level | 10mV ~ 1V ; ± [(10 + fm)% + 10mV] fm: test frequency [MHz] |
≤1MHz : 10mV ~ 5V ; ± [(10 + fm)% + 1mV] >1MHz : 10mV ~ 1V ; ± [(10 + fm)% + 1mV] fm: test frequency [MHz] |
|||
Output Impedance | 100Ω, 25Ω | 100Ω, 25Ω, OFF | |||
Measurement Display Range | L | 0.00001uH ~ 99.999MH | |||
C | 0.00001pF ~ 999.999F | ||||
R, Z | 0.01mΩ ~ 9999.99MΩ | ||||
DCR | -- | 0.01mΩ ~ 999.99MΩ | |||
Q, D | 0.00001 ~ 99999 | ||||
θ | -90.00° ~ 90.00° | ||||
Basic Accuracy | Z | ± 1.5% | ± 0.1% | ||
θ | ± 0.3° | ± 0.04° | |||
DCR | -- | ± 0.1% | |||
Measurement Speed | Very Fast : 7ms, Fast : 15ms, Medium : 150ms, Slow : 295ms | ||||
Communication Interface | RS-232C, Handler, USB storage, External bias current control, GPIB (option), LAN (option) | ||||
Measurement Functions | Trigger Mode | Internal, Manual, External, Bus | |||
Range Switching Mode | Auto, Hold | ||||
Equivalent Circuit Mode | Series, Parallel | ||||
Judgment | Compare, Bin-sorting | ||||
Correction | Open/Short Zeroing, Load Correction |
Checking with Chroma...
Model Number | Test Frequencies | Basic Accuracy |
---|---|---|
11021 LCR Meter | 100Hz, 120Hz, 1kHz and 10kHz (9.6kHz) (11021) 1kHz, 10kHz, 40kHz, 50kHz (11021-L) |
0.1% (11021), 0.2% (11021-L) |
11022 and 11025 LCR Meters | 0Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, 100kHz | ±0.1% |
11050 HF LCR Meter | 75kHZ~30MHz (11050-30M), 1kHz~10MHz (11050), 60Hz~5MHz (11050-5M) | 0.1% |
11020 Capacitance Meter | 100Hz, 120Hz, 1kHz | 0.1% |
13350 Automatic Transformer Tester | 20Hz~200kHz, ± (0.1% + 0.01Hz), 20Hz~200kHz, ± (0.1% + 0.01Hz), Resolution : 0.001Hz (<1kHz) | ±0.1% |
3250/3252/3302 Transformer Test System | 20Hz~200kHz/1MHz, 0.02% accuracy | 0.1% |
3312 Telecom Transformer Test System | 20Hz~1MHz, 0.02% accuracy | 0.1% |
1320 Bias Current Source | 20Hz~200kHz, 20Hz~1MHz | |
11300 Bias Current Test System | 20Hz to 1MHz | |
A132501 Test Fixture of Auto Transformer Scanning Box Model |
Note: All trademarks that appear on this website are the property of their respective owners.
The Chroma 11020 Capacitance Meter is a high-speed precision Capacitance Meter. Provides 100Hz, 120Hz, and 1kHz test frequencies. Measurement time is only 5 milliseconds in 1kHz, and less than 15 milliseconds in 100Hz and 120Hz test frequencies. Combine with 0.1% basic accuracy and standard Handler interface, enable the Chroma 11020 can be used on high speed production line for various capacitors.
Parameters / Characteristics | Specifications | ||
---|---|---|---|
11020 | |||
Test Signal | Test Frequency | 100Hz, 120Hz, 1kHz | |
Measurement Range | 0.1pF ~ 3.999F | ||
Basic Accuracy | 0.1% | ||
Measurement Speed | 5ms in 1kHz, 15ms in 100Hz/120Hz | ||
Display | 240 x 64 dot-matrix LCD display |
Checking with Chroma...
Model Number | Test Frequencies | Basic Accuracy |
---|---|---|
11021 LCR Meter | 100Hz, 120Hz, 1kHz and 10kHz (9.6kHz) (11021) 1kHz, 10kHz, 40kHz, 50kHz (11021-L) |
0.1% (11021), 0.2% (11021-L) |
11022 and 11025 LCR Meters | 0Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, 100kHz | ±0.1% |
11050 HF LCR Meter | 75kHZ~30MHz (11050-30M), 1kHz~10MHz (11050), 60Hz~5MHz (11050-5M) | 0.1% |
11020 Capacitance Meter | 100Hz, 120Hz, 1kHz | 0.1% |
13350 Automatic Transformer Tester | 20Hz~200kHz, ± (0.1% + 0.01Hz), 20Hz~200kHz, ± (0.1% + 0.01Hz), Resolution : 0.001Hz (<1kHz) | ±0.1% |
3250/3252/3302 Transformer Test System | 20Hz~200kHz/1MHz, 0.02% accuracy | 0.1% |
3312 Telecom Transformer Test System | 20Hz~1MHz, 0.02% accuracy | 0.1% |
1320 Bias Current Source | 20Hz~200kHz, 20Hz~1MHz | |
11300 Bias Current Test System | 20Hz to 1MHz | |
A132501 Test Fixture of Auto Transformer Scanning Box Model |
Note: All trademarks that appear on this website are the property of their respective owners.
Acquired from many years of marketing experiences and cumulative results, Chroma 13350 is the newest generation of Automatic Transformer Tester that not only retains the merits of old 3250 model but also has many new functions including the combination of measurement unit and scan box to reduce measurement error caused by long wire, C.T. test fixture and 80/20 channels scan box support, USB interface for test conditions back-up, LAN communication interface, separate setting of test frequency/voltage/speed, Fail Lock function and Auto Test. It solves the performance and quality problems as well as human errors occurred on production line for the transformer industry today.
For instance: To reduce human errors on production line, the 13350 Fail Lock function is able to lock the defect DUT (Device Under Test) when the test is done to prevent it from flowing out accidently. In order to cut down the time for placement, the 13350 Auto Test function can conduct test directly without pressing the trigger key. In addition, the 13350 adopts the design of dual CPU to increase the test speed by processing the measurement and display units simultaneously.
The compensation function of 13350 can do OPEN/SHORT for individual channel to solve the errors due to different layout on various fixtures.
13350 provides 20Hz-200kHz test frequency and scan test items to cover low voltage test parameters for various transformers including Inductance (L), Leakage (Lk) , Turn-Ratio, DC Resistance (DCR), Impedance (Z), Stray Capacity (C), Quality Factor (Q), Equivalent Series Resistance (ESR), Pin Short (PS), Winding Phase (PH) and Balance.
* New features compared to Chroma 3250 Series
Parameters / Characteristics | Specifications | |||
---|---|---|---|---|
11022 | ||||
Main Function | Transformer Scanning Test | |||
Test Parameter | Transformer Scanning | Turn Ratio, Phase, Turn, L, Q, Leakage L, Balance, ACR, Cp, DCR, Pin Short | ||
Test Signal | Test Level | Turn | 10mV~10V, ±10% 10mV/step | |
Others | 10mV~2V, ±10% 10mV/step | |||
Test Frequency | Turn | 20Hz~200kHz, ± (0.1% + 0.01Hz), Resolution: 0.01Hz | ||
Others | 20Hz~200kHz, ± (0.1% + 0.01Hz), Resolution : 0.001Hz (<1kHz) | |||
Output Impedance | Turn | 10Ω, when level≤2V / 50Ω, when level > 2V | ||
Others | Constant = OFF : Varies as range resistors ; Constant = 320X : 100Ω ±5% ; Constant = 107X : 25Ω ±5% Constant=106X : 100mA ±5% (1V setting); for inductive load less than 10Ω,10Ω±10%, for impedance ≥10Ω |
|||
Measurement Display Range | L, LK | 0.00001µH~9999.99H | ||
C | 0.001pF~999.999mF | |||
Q, D | 0.00001~99999 | |||
Z, X, R | 0.0001Ω~999.999MΩ | |||
θ | -90.00°~ +90.00° | |||
DCR | 0.01mΩ~99.999MΩ | |||
Turn,Ratio | 0.01~99999.99 turns (Secondary voltage less than 100 Vrms) | |||
Ratio (dB) | -39.99dB~+99.99dB (secondary voltage less than 100 Vrms) | |||
Pin-Short | 11 pairs, between pin to pin | |||
Basic Accuracy | L, LK, C, Z, X, Y, R, DCR | ±0.1% (1kHz if AC parameter) | ||
DCR | ±0.5% | |||
θ | ±0.04°(1kHz) | |||
Turn, Ratio (dB) | ±0.5% (1kHz) | |||
Measurement Speed (Fast) | L, LK, C, Z, X, Y, R, Q, D,θ | 50 meas./sec. | ||
DCR | 12 meas./sec. | |||
Turn, Ratio (dB) | 10 meas./sec. | |||
Judge | Transformer Scanning | PASS/FAIL judge of all test parameters output from Handler interface, 100 bin sorting for Lk | ||
Memory | 15 instrument setups, expansion is possible via memory card | |||
Trigger | Internal, Manual, External | |||
Display | Color 640x480 LCD panel | |||
Equivalent Circuit Mode | Series, Parallel | |||
Correction Function | Open/Short Zeroing, Load correction |
Checking with Chroma...
Model Number | Test Frequencies | Basic Accuracy |
---|---|---|
11021 LCR Meter | 100Hz, 120Hz, 1kHz and 10kHz (9.6kHz) (11021) 1kHz, 10kHz, 40kHz, 50kHz (11021-L) |
0.1% (11021), 0.2% (11021-L) |
11022 and 11025 LCR Meters | 0Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, 100kHz | ±0.1% |
11050 HF LCR Meter | 75kHZ~30MHz (11050-30M), 1kHz~10MHz (11050), 60Hz~5MHz (11050-5M) | 0.1% |
11020 Capacitance Meter | 100Hz, 120Hz, 1kHz | 0.1% |
13350 Automatic Transformer Tester | 20Hz~200kHz, ± (0.1% + 0.01Hz), 20Hz~200kHz, ± (0.1% + 0.01Hz), Resolution : 0.001Hz (<1kHz) | ±0.1% |
3250/3252/3302 Transformer Test System | 20Hz~200kHz/1MHz, 0.02% accuracy | 0.1% |
3312 Telecom Transformer Test System | 20Hz~1MHz, 0.02% accuracy | 0.1% |
1320 Bias Current Source | 20Hz~200kHz, 20Hz~1MHz | |
11300 Bias Current Test System | 20Hz to 1MHz | |
A132501 Test Fixture of Auto Transformer Scanning Box Model |
Note: All trademarks that appear on this website are the property of their respective owners.
The 3250/3252/3302 Transformer Test System are the precision test systems, designed for transformer production line or incoming/ outgoing inspection in quality control process, with high stability and high reliability.
The 3250/3252 provide 20Hz-200kHz tes t frequencies, and 3302 provides 20Hz-1MHz test frequencies. In addition to transformer scanning test function, the 3252/3302 have LCR Meter function. In test items, The 3250/3252/3302 cover most of transformer's low-voltage test parameters which include primary test parameters as Inductance, Leakage Inductance, Turns-Ratio, DC resistance, Impedance, and Capacitance (between windings) etc.; secondary test parameters as Quality Factor and ESR etc.; and pin-short test function. High-speed digital sampling measurement technology combined with scanning test fixture (A132501) design, improve low-efficiency transformer inspection to be more accurate and faster.
The 3250/3252/3302 even provide several output impedance selection to solve inductance measurement error problem caused by different test current caused by different output impedance provided by different LCR Meters. And, equivalent turns-ratio calculated from measured inductance of windings is also provided to improve turnsratio measurement error problem caused by large leakage magnetic flux in transformer with low permeability magnetic core.
In addition to transformer scanning test function, the 3252/3302 have LCR Meter function, can be used in component incoming/outgoing inspection, analysis and automatic production line.
Parameters / Characteristics | Specifications | |||||
---|---|---|---|---|---|---|
3250 | 3252 | 3302 | ||||
Main Function | Transformer Scanning Test | Transformer Scanning Test + LCR Meter | ||||
Test Parameter | Transformer Scanning | Turn Ratio, Phase, Turn, L, Q, Leakage L, Balance, ACR, Cp, DCR, Pin Short | ||||
LCR METER | - | L, C, R, |Z|, Y, DCR, Q, D, R, X,θ, Ratio (dB) | ||||
Test Signal | Test Level | Turn | 10mV~10V, ±10% 10mV/step | |||
Others | 10mV~2V, ±10% 10mV/step | |||||
Test Frequency | Turn | 1kHz~200kHz, ± (0.1% + 0.01Hz), Resolution: 0.01 Hz | 1kHz~1MHz, ±(0.1%+0.01Hz), Resolution : 0.01 Hz | |||
Others | 20Hz~200kHz, ± (0.1% + 0.01Hz), Resolution : 0.001 Hz (<1kHz) | 20Hz~1MHz, ±(0.1%+0.01Hz), Resolution 0.001 Hz (<1kHz) | ||||
Output Impedance Display | Turn | 10Ω, when level≤2V / 50Ω, when level > 2V | ||||
Others | Constant = OFF : Varies as range resistors ; Constant = 320X : 100Ω ±5% ; Constant = 107X : 25Ω ±5% Constant=106X : 100mA ±5% (1V setting); for inductive load less than 10Ω,10Ω±10%, for impedance ≥10Ω |
|||||
Measurement Display Range | L, LK | 0.00001µH~9999.99H | ||||
C | 0.001pF~999.999mF | |||||
Q, D | 0.00001~99999 | |||||
Z, X, R | 0.0001Ω~999.999MΩ | |||||
Y | 0.01nS~99.9999S | |||||
θ | -90.00°~ +90.00° | |||||
DCR | 0.01mΩ~99.999MΩ | |||||
Turn,Ratio | 0.01~99999.99 turns (Secondary voltage less than 100 Vrms) | |||||
Ratio (dB) | -39.99dB~+99.99dB (secondary voltage less than 100 Vrms) | |||||
Pin-Short | 11 pairs, between pin to pin | |||||
Basic Accuracy | L, LK, C, Z, X, Y, R, DCR | ±0.1% (1kHz if AC parameter) | ||||
DCR | ±0.5% | |||||
θ | ±0.04°(1kHz) | |||||
Turn, Ratio (dB) | ±0.5% (1kHz) | |||||
Measurement Speed (Fast) | L, LK, C, Z, X, Y, R, Q, D,θ | 80 meas./sec. | ||||
DCR | 50 meas./sec. | |||||
Turn, Ratio (dB) | 10 meas./sec. | |||||
Judge | Transformer Scanning | PASS/FAIL judge of all test parameters output from Handler interface, 100 bin sorting for Lk | ||||
LCR METER | - | 10 bins for sorting & bin sum count output from Handler interface/PASS/FAIL judge output from Handler interface | ||||
Memory | 15 instrument setups, expansion is possible via memory card | |||||
Trigger | Internal, Manual, External | |||||
Display | 320x240 dot-matrix LCD display | |||||
Equivalent Circuit Mode | Series, Parallel | |||||
Correction Function | Open/Short Zeroing, Load correction |
Checking with Chroma...
Model Number | Test Frequencies | Basic Accuracy |
---|---|---|
11021 LCR Meter | 100Hz, 120Hz, 1kHz and 10kHz (9.6kHz) (11021) 1kHz, 10kHz, 40kHz, 50kHz (11021-L) |
0.1% (11021), 0.2% (11021-L) |
11022 and 11025 LCR Meters | 0Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, 100kHz | ±0.1% |
11050 HF LCR Meter | 75kHZ~30MHz (11050-30M), 1kHz~10MHz (11050), 60Hz~5MHz (11050-5M) | 0.1% |
11020 Capacitance Meter | 100Hz, 120Hz, 1kHz | 0.1% |
13350 Automatic Transformer Tester | 20Hz~200kHz, ± (0.1% + 0.01Hz), 20Hz~200kHz, ± (0.1% + 0.01Hz), Resolution : 0.001Hz (<1kHz) | ±0.1% |
3250/3252/3302 Transformer Test System | 20Hz~200kHz/1MHz, 0.02% accuracy | 0.1% |
3312 Telecom Transformer Test System | 20Hz~1MHz, 0.02% accuracy | 0.1% |
1320 Bias Current Source | 20Hz~200kHz, 20Hz~1MHz | |
11300 Bias Current Test System | 20Hz to 1MHz | |
A132501 Test Fixture of Auto Transformer Scanning Box Model |
Note: All trademarks that appear on this website are the property of their respective owners.
The 3312 Telecom Transformer Test System is a precision test system, designed for telecom transformer production line or incoming/ outgoing inspection in quality control process, with high stability and high reliability.
The 3312 provides 20Hz-1MHz test frequencies. In addition to transformer scanning test function, the 3312 has LCR Meter function. In test items, The 3312 covers most of telecom transformer's low-voltage test parameters which include telecom test parameters as Return Loss (RLOS), Reflected Impedance (Zr), Insertion Loss (ILOS), Frequency response (FR), and Longitudinal Balance (LBAL) etc.; primary test parameters of general transformer as Inductance, Leakage Inductance, Turns -Ratio, DC resistance, Impedance, and Capacitance (between windings) etc.; secondary test parameters of general transformer as Quality Factor and ESR etc.; and pin-short test function. High-speed digital sampling measurement technology combined with scanning test fixture (A132501) design, improve low-efficiency telecom transformer inspection to be more accurate and faster.
The 3312 even provides several output impedance selection to solve inductance measurement error problem caused by different test current caused by different output impedance provided by different LCR Meters.
Parameters / Characteristics | Specifications | ||
---|---|---|---|
3312 | |||
Test Signal | Test Frequency | 20Hz~1MHz, 0.02% accuracy | |
Basic Accuracy | 0.1% | ||
Inductance/ Turn Ratio Measurement Speed | 80meas./sec | ||
DCR Measurement Speed | 50meas./sec | ||
Display | 320x240 dot-matrix LCD display |
Checking with Chroma...
Model Number | Test Frequencies | Basic Accuracy |
---|---|---|
11021 LCR Meter | 100Hz, 120Hz, 1kHz and 10kHz (9.6kHz) (11021) 1kHz, 10kHz, 40kHz, 50kHz (11021-L) |
0.1% (11021), 0.2% (11021-L) |
11022 and 11025 LCR Meters | 0Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, 100kHz | ±0.1% |
11050 HF LCR Meter | 75kHZ~30MHz (11050-30M), 1kHz~10MHz (11050), 60Hz~5MHz (11050-5M) | 0.1% |
11020 Capacitance Meter | 100Hz, 120Hz, 1kHz | 0.1% |
13350 Automatic Transformer Tester | 20Hz~200kHz, ± (0.1% + 0.01Hz), 20Hz~200kHz, ± (0.1% + 0.01Hz), Resolution : 0.001Hz (<1kHz) | ±0.1% |
3250/3252/3302 Transformer Test System | 20Hz~200kHz/1MHz, 0.02% accuracy | 0.1% |
3312 Telecom Transformer Test System | 20Hz~1MHz, 0.02% accuracy | 0.1% |
1320 Bias Current Source | 20Hz~200kHz, 20Hz~1MHz | |
11300 Bias Current Test System | 20Hz to 1MHz | |
A132501 Test Fixture of Auto Transformer Scanning Box Model |
Note: All trademarks that appear on this website are the property of their respective owners.
The 1320 Bias Current Source output can be controlled by LCR Meter Model 3302/3252/11022/ 11025 directly. The 1320S connected externally can output current up to 100A. The bias current scan frequency triggered automatically or manually can analyze the iron core characteristics in inductor for quality inspection and product feature analysis. They are the best measurement instruments combination for inductor test.
Parameters / Characteristics | Specifications | |||
---|---|---|---|---|
1310 | 1320 | |||
Frequency Response | 20Hz~200kHz | 20Hz~1MHz | ||
Output Capability | 0.001A~10.00A, 90W output capability | 0.001A~20.00A, 150W output capability, maximum 100Adc extendable with 1320S | ||
DCR measurement capability | 0.001Ω~199.99Ω |
Checking with Chroma...
Model Number | Test Frequencies | Basic Accuracy |
---|---|---|
11021 LCR Meter | 100Hz, 120Hz, 1kHz and 10kHz (9.6kHz) (11021) 1kHz, 10kHz, 40kHz, 50kHz (11021-L) |
0.1% (11021), 0.2% (11021-L) |
11022 and 11025 LCR Meters | 0Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, 100kHz | ±0.1% |
11050 HF LCR Meter | 75kHZ~30MHz (11050-30M), 1kHz~10MHz (11050), 60Hz~5MHz (11050-5M) | 0.1% |
11020 Capacitance Meter | 100Hz, 120Hz, 1kHz | 0.1% |
13350 Automatic Transformer Tester | 20Hz~200kHz, ± (0.1% + 0.01Hz), 20Hz~200kHz, ± (0.1% + 0.01Hz), Resolution : 0.001Hz (<1kHz) | ±0.1% |
3250/3252/3302 Transformer Test System | 20Hz~200kHz/1MHz, 0.02% accuracy | 0.1% |
3312 Telecom Transformer Test System | 20Hz~1MHz, 0.02% accuracy | 0.1% |
1320 Bias Current Source | 20Hz~200kHz, 20Hz~1MHz | |
11300 Bias Current Test System | 20Hz to 1MHz | |
A132501 Test Fixture of Auto Transformer Scanning Box Model |
Note: All trademarks that appear on this website are the property of their respective owners.
Chroma 11300 bias current test system is an integration test system of LCR Meter and Bias Current Source.
It consists of Chroma 3252/3302 series Automatic Component Analyzer and Chroma 1320 series Bias Current Source. The Chroma 1320 series bias current source output can be controlled by Chroma 3252/3302 LCR meter directly. The bias current output capacity can be selected up to 100A to satisfy various testing in R&D, QC, QA, and production applications.
This system is designed for large DC current testing, up to 300A. The connector between bias current sources is low ESR (This system provides power choke characteristic sweep graph analysis through Windows® base software or sweep function of the meter. The bias current scan triggered automatically or manually can analyze the iron core characteristics in inductor for quality inspection and product feature analysis. The Chroma 11300 is a just right test solution for magnetic choke and core used in various power supply.
Parameters / Characteristics | Specifications | ||
---|---|---|---|
11300 | |||
Stability, Frequency Response | 20Hz to 1MHz | ||
Output Current Accuracy | 3% | ||
Expansion capabilities | Up to 100A |
Checking with Chroma...
Model Number | Test Frequencies | Basic Accuracy |
---|---|---|
11021 LCR Meter | 100Hz, 120Hz, 1kHz and 10kHz (9.6kHz) (11021) 1kHz, 10kHz, 40kHz, 50kHz (11021-L) |
0.1% (11021), 0.2% (11021-L) |
11022 and 11025 LCR Meters | 0Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, 100kHz | ±0.1% |
11050 HF LCR Meter | 75kHZ~30MHz (11050-30M), 1kHz~10MHz (11050), 60Hz~5MHz (11050-5M) | 0.1% |
11020 Capacitance Meter | 100Hz, 120Hz, 1kHz | 0.1% |
13350 Automatic Transformer Tester | 20Hz~200kHz, ± (0.1% + 0.01Hz), 20Hz~200kHz, ± (0.1% + 0.01Hz), Resolution : 0.001Hz (<1kHz) | ±0.1% |
3250/3252/3302 Transformer Test System | 20Hz~200kHz/1MHz, 0.02% accuracy | 0.1% |
3312 Telecom Transformer Test System | 20Hz~1MHz, 0.02% accuracy | 0.1% |
1320 Bias Current Source | 20Hz~200kHz, 20Hz~1MHz | |
11300 Bias Current Test System | 20Hz to 1MHz | |
A132501 Test Fixture of Auto Transformer Scanning Box Model |
Note: All trademarks that appear on this website are the property of their respective owners.
There is no specification for Test Fixture of Auto Transformer Scanning Box Model A132501.
Checking with Chroma...
Model Number | Test Frequencies | Basic Accuracy |
---|---|---|
11021 LCR Meter | 100Hz, 120Hz, 1kHz and 10kHz (9.6kHz) (11021) 1kHz, 10kHz, 40kHz, 50kHz (11021-L) |
0.1% (11021), 0.2% (11021-L) |
11022 and 11025 LCR Meters | 0Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, 100kHz | ±0.1% |
11050 HF LCR Meter | 75kHZ~30MHz (11050-30M), 1kHz~10MHz (11050), 60Hz~5MHz (11050-5M) | 0.1% |
11020 Capacitance Meter | 100Hz, 120Hz, 1kHz | 0.1% |
13350 Automatic Transformer Tester | 20Hz~200kHz, ± (0.1% + 0.01Hz), 20Hz~200kHz, ± (0.1% + 0.01Hz), Resolution : 0.001Hz (<1kHz) | ±0.1% |
3250/3252/3302 Transformer Test System | 20Hz~200kHz/1MHz, 0.02% accuracy | 0.1% |
3312 Telecom Transformer Test System | 20Hz~1MHz, 0.02% accuracy | 0.1% |
1320 Bias Current Source | 20Hz~200kHz, 20Hz~1MHz | |
11300 Bias Current Test System | 20Hz to 1MHz | |
A132501 Test Fixture of Auto Transformer Scanning Box Model |
Note: All trademarks that appear on this website are the property of their respective owners.
The 1062A/1075 LCR Meters are the measurement instruments for passive components. They are applicable to the automatic manufacturers for passive components in material inspection and production line. This series of LCR Meters can fully fulfill the fast and accurate requirements for automatic production. The functions of 8-level counting, pass/fail judgment, and 10 sets of internal save and recall settings meet the production line requirements for speed and quality, thus make this series of LCR Metes the best measurement instruments for material and production line inspection for passive components.
Parameters / Characteristics | Specifications | |||
---|---|---|---|---|
1075 | 1062A | |||
Test Signal | Test Frequency | 20Hz ~ 200kHz, 0.2% programmable test frequency | 40Hz ~ 200kHz, 30 Steps | |
Measurement Range | 0.01mΩ~99.999mΩ with 5 digits resolution | |||
Basic Accuracy | 0.1% |
Checking with Chroma...
Model Number | Test Frequencies | Basic Accuracy |
---|---|---|
11021 LCR Meter | 100Hz, 120Hz, 1kHz and 10kHz (9.6kHz) (11021) 1kHz, 10kHz, 40kHz, 50kHz (11021-L) |
0.1% (11021), 0.2% (11021-L) |
11022 and 11025 LCR Meters | 0Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, 100kHz | ±0.1% |
11050 HF LCR Meter | 75kHZ~30MHz (11050-30M), 1kHz~10MHz (11050), 60Hz~5MHz (11050-5M) | 0.1% |
11020 Capacitance Meter | 100Hz, 120Hz, 1kHz | 0.1% |
13350 Automatic Transformer Tester | 20Hz~200kHz, ± (0.1% + 0.01Hz), 20Hz~200kHz, ± (0.1% + 0.01Hz), Resolution : 0.001Hz (<1kHz) | ±0.1% |
3250/3252/3302 Transformer Test System | 20Hz~200kHz/1MHz, 0.02% accuracy | 0.1% |
3312 Telecom Transformer Test System | 20Hz~1MHz, 0.02% accuracy | 0.1% |
1320 Bias Current Source | 20Hz~200kHz, 20Hz~1MHz | |
11300 Bias Current Test System | 20Hz to 1MHz | |
A132501 Test Fixture of Auto Transformer Scanning Box Model |