SCTH series current sensors are mainly used for measuring currents in medical equipment, smart power grids, and high-precision inverters, offering more reliable and higher-performance solutions for the manufacturing and use of relevant equipment.
Maximum accuracy up to 0.05%, which effectively avoids transmission loss and interference for more accurate results.
Extremely low output noise, significantly reducing noise pollution and ensuring the physical and psychological safety of indoor operators.
Exceptional anti-interference capabilities for use in confined spaces, reducing installation costs and ensuring more accurate results by minimizing other sources of interference.
The current sensor can be used immediately after powering on, saving valuable time for test engineers and ensuring faster and improved measurements.
Parameters / Characteristics | Specifications | ||||||||
---|---|---|---|---|---|---|---|---|---|
SCTH60 | SCTH200 | SCTH600 | SCTH1000 | ||||||
DC Current | 0 - 60A | 0 - 200A | 0 - 600A | 0 - 1000A | |||||
AC Current | 60APeak | 200APeak | 600APeak | 1000APeak | |||||
Measurement Accuracy | ±(0.05% of rdg + 15µA) | ||||||||
Measurement Bandwidth | DC - 800KHz | DC - 500KHz | DC - 300KHz | DC - 300KHz | |||||
Ratio KN | 1:600 | 1:1000 | 1:1500 | 1:2000 | |||||
Resistance Rm | 0 - 25Ω | 0 - 12Ω | 0 - 3Ω | ||||||
Aperture | Φ 28mm | Φ 30.9mm | |||||||
Connector | DB9 | ||||||||
Connector | ±12V ~ ±15V | ±15V ~ ±24V | |||||||
Linearity | < 5ppm | ||||||||
Low Temperature Coefficient | < 0.1ppm/K |
Checking with Suita...
Model Number | Accuracy | Excellent linearity | Low temperature coefficient | Start-up warm-up time |
---|---|---|---|---|
SCTH Current Sensors | 0.008% | <5ppm | <0.1ppm/K | No |
SCTX Current Sensors | 0.05% | <5ppm | <0.1ppm/K | No |
Note: All trademarks that appear on this website are the property of their respective owners.
SCTX series current sensors are mainly used for measuring currents in medical equipment, smart power grids, and high-precision inverters, offering more reliable and higher-performance solutions for the manufacturing and use of relevant equipment.
Maximum accuracy up to 0.008%, which effectively avoids transmission loss and interference for more accurate results.
Extremely low output noise, significantly reducing noise pollution and ensuring the physical and psychological safety of indoor operators.
Exceptional anti-interference capabilities for use in confined spaces, reducing installation costs and ensuring more accurate results by minimizing other sources of interference.
The current sensor can be used immediately after powering on, saving valuable time for test engineers and ensuring faster and improved measurements.
Parameters / Characteristics | Specifications | ||||||||
---|---|---|---|---|---|---|---|---|---|
SCTH60 | SCTH200 | SCTH600 | SCTH1000 | ||||||
DC Current | 0 - 60A | 0 - 200A | 0 - 600A | 0 - 1000A | |||||
AC Current | 60APeak | 200APeak | 600APeak | 1000APeak | |||||
Measurement Accuracy | ±(0.05% of rdg + 15µA) | ||||||||
Measurement Bandwidth | DC - 800KHz | DC - 500KHz | DC - 300KHz | DC - 300KHz | |||||
Ratio KN | 1:600 | 1:1000 | 1:1500 | 1:2000 | |||||
Resistance Rm | 0 - 25Ω | 0 - 12Ω | 0 - 3Ω | ||||||
Aperture | Φ 28mm | Φ 30.9mm | |||||||
Connector | DB9 | ||||||||
Connector | ±12V ~ ±15V | ±15V ~ ±24V | |||||||
Linearity | < 5ppm | ||||||||
Low Temperature Coefficient | < 0.1ppm/K |
Checking with Suita...
Model Number | Accuracy | Excellent linearity | Low temperature coefficient | Start-up warm-up time |
---|---|---|---|---|
SCTH Current Sensors | 0.008% | <5ppm | <0.1ppm/K | No |
SCTX Current Sensors | 0.05% | <5ppm | <0.1ppm/K | No |
Note: All trademarks that appear on this website are the property of their respective owners.